DGMS Approval Standards for Flameproof, Intrinsically Safe & Electrical Equipment | EX-d / EX-ia / IS Standards Explained


⚑ Flameproof, Intrinsically Safe & Electrical Equipment – DGMS Approval Standards Mining electrical equipment operates in methane-rich, explosive atmospheres, especially in underground coal mines.
To prevent ignition, DGMS mandates strict testing & approval under:
  • Flameproof (FLP / Ex-d)
  • Intrinsically Safe (IS / Ex-ia, Ex-ib)
  • Non-sparking / safe-area equipment
This blog explains DGMS standards, testing, certification workflow & statutory requirements in simple OnlineMiningExam style.

πŸ”Ή 1. Why DGMS Approval is Mandatory for Electrical Equipment? 

 Because underground coal mines contain:
  • Methane gas (CHβ‚„)
  • Coal dust
  • Fire/explosion hazards
DGMS ensures: 

βœ” No spark β†’ No explosion
βœ” Safe electrical circuits
βœ” Internationally compliant EX standards
βœ” Operators protected from electrical hazards

πŸ”Ή 2. Indian & International Standards Used by DGMS
Protection Type Standard Used
Flameproof (FLP) IS/IEC 60079-1 (Ex-d)
Intrinsic Safety (IS) IS/IEC 60079-11 (Ex-ia / Ex-ib)
Dust-protected IS/IEC 60079-31
Non-sparking (Ex-n) IS/IEC 60079-15
Cable glands IS/IEC 60079-0 / 1 / 7
General electrical safety IS 5572 / IS 13408 / IS 2148
DGMS requires compliance with BIS + IECEx/ATEX for imported equipment.

πŸ”Ή 3. Flameproof Equipment (FLP) – Ex-d 

  πŸ”₯ What is Flameproof? 

 A housing/enclosure that:
  • Contains internal explosion
  • Prevents flame propagation
  • Resists pressure surges
Typical examples:
  • FLP Motors
  • FLP Switchgear / Starters
  • FLP Junction Boxes
  • FLP Lighting Fittings
  • FLP Cable Glands
  • FLP Gas Detectors

⭐ Key DGMS Requirements for FLP Equipment
  1. Flamepath dimensions must match approved drawing
  2. Smoothness (Ra < 6.3 Β΅m)
  3. No scratches or damage
  4. Gas test clearance maintained
  5. Enclosure withstands 1.5 Γ— maximum pressure
  6. Joint length & gap within IS standards
  7. BIS / IECEx certification mandatory
  8. Proper earthing
  9. Cable glands must be FLP type

πŸ”Ή 4. Intrinsically Safe Equipment (IS) – Ex-ia / Ex-ib 

  🧯 What is Intrinsic Safety?

Limiting energy, voltage, current, and temperature so that the device cannot ignite gas even under fault conditions. Common IS devices:
  • Gas detectors
  • Communication systems
  • Cap lamps
  • Sensors & automation
  • Telemetry
  • Proximity Warning Systems (PWS)

⭐ IS Equipment DGMS Requirements
  • Safety parameters must be permanently marked
  • Energy storage (L, C) must be limited
  • Ex-test report (ExTR) mandatory
  • QAN/QAR mandatory
  • Fault tests must pass 2-fault conditions (for Ex-ia)

πŸ”Ή 5. Non-Sparking Equipment (Ex-n)

Used in:
  • Surface mines
  • Non-gassy underground areas
Not allowed in: ❌ Degree II & III mines
❌ Hazardous zones 0 & 1

πŸ”Ή 6. Hazardous Area Classification – DGMS Standards
Zone Condition Example
Zone 0 Gas present continuously Sealed off areas
Zone 1 Gas likely during operation Development headings
Zone 2 Gas unlikely, but possible Return airways
Usage Restrictions
Equipment Zone
Ex-ia Zone 0 / 1 / 2
Ex-ib Zone 1 / 2
Ex-d Zone 1 / 2
Ex-n Zone 2

πŸ”Ή 7. DGMS Approval Process for Electrical Equipment

Manufacturer/IAR β†’ Submit Form B/C ↓ Document Scrutiny by DGMS ↓ CIMFR/ERTL/CPRI Testing ↓ Factory QAR Audit ↓ Field Trial (If Required) ↓ DGMS Approval (Form K)

πŸ”Ή 8. DGMS Testing Requirements 

  ⭐ For Flameproof Equipment
  • Spark test
  • Temperature test
  • Pressure test
  • Impact test
  • Flame transmission test
  • Flamepath measurement
⭐ For IS Equipment
  • Spark ignition test
  • Component thermal testing
  • Fault simulation
  • Energy limitation verification

πŸ”Ή 9. Typical Electrical Equipment Requiring DGMS Approval
  • Motors & switchgear
  • Lighting fittings
  • Transformers
  • Cables & glands
  • Cap lamps
  • Battery electric vehicles (BEVs)
  • Gas detectors
  • Communication systems
  • Proximity warning systems

πŸ”₯ 25 MCQs (DGMS Pattern) with Answers

1) Flameproof equipment is denoted by β€”

a) Ex-n
b) Ex-e
c) Ex-d
d) Ex-m
e) None
Ans: c

2) Intrinsically safe circuits follow β€”

a) IS 2148
b) IS 5572
c) IS/IEC 60079-11
d) IS 3815
e) None
Ans: c

3) Flamepath should be β€”

a) Rough
b) Painted
c) Smooth and within tolerance
d) Plastic-coated
e) None
Ans: c

4) Ex-ia equipment is suitable for β€”

a) Zone 2 only
b) Zone 1 only
c) Zone 0/1/2
d) Surface only
e) None
Ans: c

5) FLP motors prevent β€”

a) Water
b) Smoke
c) Internal flame propagation
d) Heat
e) None
Ans: c

6) IS equipment limits β€”

a) Energy
b) Voltage
c) Current
d) All of the above
e) None
Ans: d

7) IECEx relates to β€”

a) Vehicles
b) Explosion protection
c) Timber
d) Temperature
e) None
Ans: b

8) Ex-d testing includes β€”

a) Colour test
b) Pressure & flame transmission test
c) Sticker test
d) Water test
e) None
Ans: b

9) Cap lamps are normally β€”

a) Ex-d
b) Ex-ia
c) Ex-n
d) Ex-e
e) None
Ans: b

10) Ex-n equipment allowed in β€”

a) Zone 0
b) Zone 1
c) Zone 2
d) All zones
e) None
Ans: c

11) Flamepath must not be β€”

a) Smooth
b) Steel
c) Damaged or scratched
d) Clean
e) None
Ans: c

12) IS circuits tested for β€”

a) One fault only
b) Two faults (Ex-ia)
c) Zero fault
d) Not tested
e) None
Ans: b

13) DGMS form for approval is β€”

a) Form J
b) Form L
c) Form K
d) Form A
e) None
Ans: c

14) Gas detectors require β€”

a) UV test
b) Ex certification
c) Water test
d) No test
e) None
Ans: b

15) Testing labs include β€”

a) Film studio
b) ETDC/ERTL
c) CPRI
d) CIMFR
e) All of these
Ans: e

16) Flameproof equipment prevents ignition in β€”

a) Kitchens
b) Methane atmospheres
c) Car parks
d) Offices
e) None
Ans: b

17) Ex-e means β€”

a) Extra dangerous
b) Increased safety
c) External engine
d) Energy excess
e) None
Ans: b

18) IS equipment required in β€”

a) Degree III mines
b) Degree II mines
c) Zone 0 areas
d) Gassy mines
e) All of these
Ans: e

19) Ex markings must be β€”

a) Hidden
b) Permanently engraved
c) removable
d) Sticker based
e) None
Ans: b

20) Equipment safety depends on β€”

a) Colour
b) Material
c) Approved design
d) Workmanship
e) All except (a)
Ans: e

21) Flameproof enclosure thickness β€”

a) Variable
b) Optional
c) Fixed as per drawing
d) Random
e) None
Ans: c

22) For imported equipment DGMS requires β€”

a) ATEX
b) IECEx
c) BIS compliance
d) Indian testing
e) All of these
Ans: e

23) Flamepaths must be checked during β€” a) Shipping
b) Maintenance
c) Driving
d) Painting
e) None
Ans: b

24) Non-sparking equipment is β€”

a) Ex-d
b) Ex-ia
c) Ex-n
d) Ex-e
e) None
Ans: c

25) Goal of DGMS electrical approval β€”

a) Increase sales
b) Reduce weight
c) Prevent explosions & protect miners
d) Improve colour
e) None
Ans: c

πŸ”š Conclusion

Flameproof, Intrinsically Safe and Electrical equipment are the backbone of underground mining safety.
DGMS ensures that:
  • No electrical spark causes methane ignition
  • Only IEC/IS-certified equipment is used
  • Mines maintain highest electrical safety standards
  • Imported equipment meets Indian laws
A deep understanding of EX standards is essential for DGMS exam aspirants and mine engineers.

πŸš€  Download DGMS EX Equipment Notes at OnlineMiningExam.com
πŸ“ Attempt 10,000+ DGMS MCQs
πŸ”” Join OME Telegram Channel for daily EX safety updates


{{ONLINEMININGEXAM.COM}}
India's 1st Online Mining Academy Prepare for DGMS 1st Class & 2nd Class Mining Manager......

OUR COURSES View More

/* Banner container */ #omxBanner { position: fixed; left: 50%; bottom: -120px; /* hidden initially */ transform: translateX(-50%); width: min(980px, calc(100% - 20px)); max-width: 980px; background: linear-gradient(90deg,#0f172a,#0b84ff); color: #fff; border-radius: 12px 12px 8px 8px; padding: 11px 14px; /* reduced (80%) */ box-shadow: 0 12px 30px rgba(3,10,30,0.45); display: flex; gap: 10px; align-items: center; z-index: 2000; transition: bottom 450ms cubic-bezier(.2,.9,.3,1), transform 250ms; font-family: system-ui, -apple-system, "Segoe UI", Roboto, "Helvetica Neue", Arial; } /* Show class slides banner up */ #omxBanner.show { bottom: 20px; } /* Left: icon / logo */ #omxBanner .left { flex: 0 0 51px; /* 80% of 64px */ height: 51px; border-radius: 6px; background: linear-gradient(135deg,#00d4ff,#0077ff); display:flex; align-items:center; justify-content:center; font-weight:700; color:#002; font-size:16px; /* reduced */ } /* Middle: text */ #omxBanner .center { flex: 1 1 auto; min-width: 0; } #omxBanner .center h4 { margin: 0 0 3px 0; font-size: 13px; /* reduced */ line-height: 1.1; letter-spacing: 0.2px; } #omxBanner .center p { margin: 0; font-size: 11px; /* reduced */ opacity: 0.95; } /* Right: CTA & close */ #omxBanner .right { display:flex; gap:6px; align-items:center; } #omxBanner .cta { background: linear-gradient(90deg,#ffb703,#fb8500); color: #07122a; border: none; padding: 8px 11px; /* reduced */ border-radius: 6px; font-weight: 700; cursor: pointer; text-decoration: none; font-size: 12px; /* reduced */ box-shadow: 0 6px 14px rgba(251,133,0,0.22); } #omxBanner .cta:active { transform: translateY(1px); } #omxBanner .closeBtn { background: transparent; border: none; color: rgba(255,255,255,0.9); font-size: 16px; /* reduced */ cursor: pointer; padding: 4px; line-height:1; } /* Mobile tweaks */ @media (max-width:600px) { #omxBanner { flex-direction: column; gap:6px; align-items:flex-start; padding:9px; bottom: 10px; width: calc(100% - 18px); left: 50%; transform: translateX(-50%); } #omxBanner .left { display:none; } #omxBanner .right { width:100%; justify-content: space-between; } #omxBanner .cta { width:48%; text-align:center; padding:8px 6px; font-size:11px; } }