🧾 DETAILED NOTES
1️⃣ Introduction
Rigid steel supports such as props, chocks, and cogs are widely used in coal and metal underground mines for roof support, controlling strata movement, and ensuring safe working conditions. DGMS prescribes minimum standards for strength, design, testing, and usage to prevent roof falls and support failures.
These supports resist vertical and lateral loads and are widely used in depillaring, development headings, galleries, and junctions.
2️⃣ Rigid Steel Props – Components
1. Prop Body: Seamless steel tube or thick-walled pipe, high crushing strength. Length varies depending on seam height (1.0 m to 3.0 m).
2. Base Plate: Thick steel plate to distribute load evenly and prevent sinking into floor strata.
3. Cap Plate / Head Plate: Receives load from roof, prevents eccentric loading, typically 150–200 mm wide.
4. Welded Joints: High-quality welds ensuring compliance with IS welding standards.
3️⃣ Chocks & Cogs – Components
Chocks: Stable structures made of fabricated steel sections (I-beams, channels) or timber blocks arranged in layers. They utilize heavy gauge steel Cap & Base Plates and Cross Bracing to prevent lateral movement.
Cogs: Rigid pillar-like structures formed by crosswise stacking of short timber blocks or steel sections. They use a cap piece and packing material, tightened by wedges.
4️⃣ Mechanical Properties (DGMS Recommended)
| Property | Requirement |
|---|---|
| Compressive Strength | Very high (≥ 300–400 kN for steel props) |
| Yield Strength | 250–350 MPa |
| Buckling Resistance | Must resist lateral deformation |
| Corrosion Resistance | Coated or painted steel |
| Fatigue Strength | Withstand long-term cyclic loading |
5️⃣ Installation & Maintenance
- Props should be installed vertically, with the base secured on a firm floor.
- Proper packing is needed between the prop head and the roof.
- Cogs must be layered crosswise to prevent shifting, and tightened using wedges.
- Regular inspection is mandatory for deformation, rust, and signs of buckling.
- Props must not be used if bent or cracked.
⚡ QUICK ONE-LINERS
- Rigid steel props provide vertical roof support.
- Minimum yield strength of steel ≥ 240 MPa.
- Steel chocks used for long-term heavy-duty support.
- Compressive strength ≥ 300 kN is expected for steel props.
- Must comply with DGMS & BIS support standards (e.g., IS 13224).
- Widely used in depillaring operations.
- Cap plate distributes the roof load uniformly.
- Corrosion-resistant coating (paint/galvanizing) is essential.
- Buckling is the major failure risk for props.
- Crosswise packing and wedges are used to tighten cogs.
🧠 DESCRIPTIVE MODEL Q&A
Q. Describe the standard components and required mechanical properties of rigid steel props, chocks, and cogs used in underground mines.
Answer:
Rigid steel supports such as props, chocks, and cogs are essential for strata control in underground mines. According to DGMS and CMR 2017, steel props are made of high-strength steel pipes with cap plates, base plates, and locking mechanisms. Steel chocks consist of multiple steel legs connected by frames and braces, while cogs are box-type assemblies built from channels or I-beams. These supports must meet minimum mechanical requirements: yield strength ≥ 240 MPa, compressive capacity ≥ 300–400 kN, high weld quality, corrosion resistance, and dimensional accuracy as per IS standards. All steel supports must be tested at DGMS-approved institutions. Installation must follow the approved support plan to ensure roof stability and worker safety.
🧮 25 MCQs (Dynamic Answers A–E)
Q1. Rigid steel props are primarily used for:
Q2. Main load-bearing property of steel props:
Q3. Chocks are built using:
Q4. Cogs resist:
Q5. Steel props must comply with:
Q6. Failure of props is mainly due to:
Q7. Cap plate is used for:
Q8. Steel props are usually made from:
Q9. Chocks provide:
Q10. Cogs are installed in:
Q11. Base plate prevents:
Q12. Steel props must be stored:
Q13. Compressive strength of steel props generally:
Q14. Timber cogs depend on:
Q15. The topmost part of a cog assembly that receives load from the roof is the:
Q16. Chocks resist:
Q17. Steel props must undergo inspection for:
Q18. Cogs are usually placed:
Q19. Corrosion of steel props is prevented by:
Q20. Chocks and cogs help control:
Q21. Props must be replaced if:
Q22. Cogs are tightened using:
Q23. Steel prop height depends on:
Q24. Steel props provide:
Q25. Roof bolting must be performed by:
🔗 INTERNAL LINKING SUGGESTIONS
| Related Topic | Read More On... |
|---|---|
| Roof Bolting Standards | Revised DGMS Standards for Resin Capsules |
| Strata Monitoring | Strata Monitoring in Longwall Workings |
| Alternative Support | Friction Stabilizers (Split Sets) |
| Testing | Pull Test & Torque Test Methods |
🚧 Master Roof Bolting & DGMS Support Standards!
Join Online Mining Exam – India’s 1st Online Mining Academy.
- DGMS Technical Notes
- Real MCQs & Solved Papers
- Complete Coal & Metal Mine Safety Coverage
🌐 www.onlineminingexam.com
📞 9971114020